Nitrous Oxide Cylinder in Bangladesh — Medical N₂O Gas Cylinder Supply
What Is a Nitrous Oxide Cylinder?
A nitrous oxide cylinder is a high-pressure steel or aluminium container that stores medical-grade nitrous oxide (N₂O) in liquefied form for controlled clinical use. Hospitals, dental clinics and surgical centres across Bangladesh rely on a properly certified nitrous oxide cylinder to support anaesthesia and analgesia procedures performed by qualified medical professionals.
Unlike medical oxygen, nitrous oxide is a pharmacologically active medical gas. That distinction matters enormously. A nitrous oxide cylinder must therefore be identified, stored, connected and administered with a level of care that reflects its clinical potency.
Product Overview
Medical Product BD supplies the nitrous oxide cylinder as part of our medical gas equipment range for hospitals, clinics and dental practices operating in Dhaka and across Bangladesh. Every nitrous oxide cylinder we handle moves through authorised medical-gas channels, arrives clearly identified, and comes with the documentation your biomedical or procurement team needs for compliance records.
Sourcing medical gas is not the same as buying general medical equipment. Purity, certification, valve compatibility and hydrostatic test currency all have to be right — because there is no margin for error in an operating theatre. Our role is to remove that uncertainty from your supply chain.
Why Choose This Product
Choosing your nitrous oxide cylinder through Medical Product BD means working with a supplier that understands medical gas handling rather than treating it as ordinary stock. We verify identification markings, advise on compatible regulators and manifold fittings, coordinate secure upright transport, and provide handover guidance for your biomedical team.
We also say no when we should. If a cylinder’s certification or test date does not check out, it does not leave our facility. That discipline is what makes a medical gas supplier worth having.
For specifications, certification details, cylinder sizes or safety documentation, contact our team — we are glad to help your facility get the right product the first time.
Key Features of Our Nitrous Oxide Cylinder Supply
- Medical-grade gas only — every nitrous oxide cylinder contains pharmaceutical-grade N₂O sourced through authorised medical-gas fillers, never industrial or automotive grade.
- Unambiguous identification — colour coding, gas name, chemical symbol and batch details are permanently marked, so theatre staff can confirm contents at a glance.
- Multiple capacity options — small portable sizes for dental clinics through to large cylinders for manifold-fed hospital systems.
- Certification documentation supplied — test dates, fill records and conformity information available for your compliance file.
- Standard valve outlets — pin-index or threaded valve configurations that mate correctly with compliant medical regulators, reducing cross-connection risk.
- Hydrostatic test currency verified — cylinders outside their test window are withdrawn, not shipped.
- Corrosion-inspected cylinder bodies — visual inspection for dents, gouges, arc burns and neck damage before dispatch.
- Valve protection fitted — caps or guards protect the valve during transit and storage.
- Secure upright transport — cylinders are restrained in the correct orientation throughout delivery.
- Regulator and fitting guidance — we help you specify pressure-control equipment that actually matches your cylinder valve.
- Restricted institutional supply — sold to registered healthcare facilities and authorised buyers only, protecting both patients and your practice.
- Dhaka same-city delivery and nationwide dispatch — Mirpur-based operations with delivery across all Dhaka thanas and onward to divisional cities.
- Bulk and contract supply — scheduled replenishment for hospitals with predictable theatre volumes.
- Empty cylinder exchange coordination — organised returns through authorised fillers; we never refill on-site or informally.
- Technical support after delivery — reachable by phone or WhatsApp for handling, storage and compatibility questions.
Nitrous Oxide Cylinder Specifications
The table below shows typical parameters for a medical nitrous oxide cylinder. Exact values differ by manufacturer, cylinder size and applicable standard.
Always confirm the actual figures from the cylinder label, stamped shoulder markings and supplier certificate before use.
| Specification | Detail |
|---|---|
| Brand | Varies by authorised medical-gas filler — confirmed at order |
| Model | Confirm from manufacturer label and certification |
| Product Type | Medical Nitrous Oxide Gas Cylinder |
| Category | Medical Gas Equipment |
| Gas Contents | Medical-grade nitrous oxide (N₂O), liquefied under pressure |
| Typical Purity | Medical/USP grade — verify on certificate of analysis |
| Capacity (Water Capacity) | 1.36 |
| Cylinder Material | Seamless steel or aluminium alloy (varies by model) |
| Weight | Varies by size; tare weight stamped on cylinder |
| Dimensions | Varies by cylinder size — confirm at order |
| Flow Rate | Determined by the regulator/anaesthesia machine, not the cylinder |
| Filling Pressure | Liquefied gas — pressure varies with temperature; see label |
| Test Pressure | Stamped on cylinder shoulder |
| Valve Outlet | Pin-index or threaded, per applicable standard |
| Voltage / Power | Not applicable — passive pressurised container |
| Working Pressure | 3 Kg/ 5 Kg |
| Technology | High-pressure seamless cylinder with medical gas valve |
| Oxygen Purity | Not applicable — this cylinder contains N₂O, not oxygen |
| Noise Level | Not applicable |
| Battery | Not applicable |
| Colour Coding | Blue (varies by national standard) |
| Certification | Manufacturer certification and hydrostatic test record supplied |
| Country of Origin | Varies by manufacturer — confirm from label/documentation |
| Warranty | Per manufacturer/supplier terms — verify before acceptance |
Benefits of a Properly Sourced Nitrous Oxide Cylinder
1. Patient safety through correct gas identity. Gas misidentification is a known cause of serious clinical incidents worldwide. A clearly marked, correctly colour-coded nitrous oxide cylinder from a traceable source is your first defence against that failure mode.
2. Regulatory and audit readiness. Hospital accreditation and inspection processes ask for medical gas documentation. Cylinders supplied with fill records and test dates make that paperwork straightforward instead of stressful.
3. Uninterrupted theatre scheduling. Reliable replenishment means anaesthesia lists are not rescheduled because a cylinder ran empty overnight.
4. Equipment protection. Correct valve type and clean, dry medical-grade gas protect your anaesthesia machines and manifolds from contamination and premature wear.
5. Reduced staff exposure risk. Cylinders in sound condition with properly seating valves leak less, which supports lower ambient N₂O levels when combined with adequate scavenging and ventilation.
6. Cost control through right-sizing. Matching cylinder capacity to actual clinical throughput reduces both wasted residual gas and excessive changeover labour.
7. A knowledgeable supplier relationship. When a fitting does not match or a test date is approaching, having a supplier who answers the phone and knows the answer saves hours.
Applications of Nitrous Oxide Cylinders in Healthcare
Below are the professional settings where a nitrous oxide cylinder is typically deployed. In every case, clinical use is directed and supervised by qualified healthcare professionals.
- Hospital operating theatres — supplying anaesthesia machines as part of a balanced anaesthetic technique.
- Dental clinics — conscious sedation for anxious patients, delivered by trained dental practitioners with appropriate equipment.
- Day-surgery and ambulatory units — short procedural sedation and analgesia support.
- Obstetric and labour wards — inhalational analgesia during labour, per institutional protocol.
- Emergency departments — procedural analgesia for painful interventions under clinician supervision.
- Orthopaedic procedure rooms — analgesia support for fracture manipulation and similar procedures.
- Paediatric treatment areas — anxiolysis and analgesia in appropriately equipped, supervised settings.
- Centralised medical gas manifold systems — cylinder banks feeding piped N₂O outlets throughout a facility.
- Endoscopy and minor procedure suites — supporting patient comfort during short interventions.
- Veterinary surgical facilities — anaesthesia support under qualified veterinary supervision.
- Ambulance and pre-hospital services — pre-mixed analgesic gas systems operated by trained EMS personnel.
- Biomedical engineering test benches — calibration and functional testing of anaesthesia delivery equipment.
Nitrous Oxide Cylinder vs Other Medical Gas Cylinders
Facilities often stock several gases side by side. Understanding how each differs helps procurement teams order correctly and helps clinical staff avoid dangerous mix-ups.
Advantages of the Nitrous Oxide Cylinder
- Rapid onset and rapid offset make it clinically manageable within short procedures.
- Reduces the required dose of other anaesthetic agents in balanced techniques.
- Well-established, long-standing role in dental and obstetric practice.
- Cylinder supply requires no electricity, so it functions during power interruptions.
- Compatible with standard anaesthesia machines and manifold infrastructure.
Limitations to Plan For
- Requires trained personnel and monitoring — this is not a plug-and-play device.
- Occupational exposure risk — chronic staff exposure requires active scavenging and room ventilation.
- Strong oxidiser — vigorously supports combustion; strict fire precautions are mandatory.
- Contents hard to gauge — pressure readings mislead until the liquid phase is gone.
- Heavy cylinders — larger sizes need trolleys and safe manual handling practice.
- Restricted availability — cannot be casually purchased, by design.
- Never a substitute for oxygen — has no role in respiratory support.
Best Use Cases
A nitrous oxide cylinder is the right choice for a registered hospital, dental practice, surgical centre or licensed healthcare facility with trained anaesthesia or sedation staff, scavenging equipment, and institutional protocols in place. For home respiratory patients, the correct products are an oxygen cylinder or an oxygen concentrator instead.
Who Should Buy This Nitrous Oxide Cylinder
Suitable Buyers
- Hospitals — government, private and specialised, with medical gas manifold systems and biomedical engineering support.
- Dental clinics and dental hospitals — practices offering conscious sedation with appropriately trained practitioners.
- Surgical and day-care centres — facilities running scheduled operating lists.
- Diagnostic and endoscopy centres — where short procedural sedation is provided under supervision.
- Maternity and obstetric hospitals — labour analgesia programmes.
- Veterinary surgical hospitals — qualified veterinary anaesthesia use.
- Medical colleges and teaching institutions — anaesthesia training departments with supervised practice.
- Emergency and ambulance services — licensed operators with trained EMS personnel.
- Biomedical equipment servicing companies — anaesthesia machine testing and commissioning.
Who Should Not Buy This Product
A nitrous oxide cylinder is not appropriate for home patients, individual consumers, caregivers managing a relative at home, catering or food businesses, or any non-clinical purchaser. If you are caring for an elderly parent, a COPD or asthma patient, or someone recovering from surgery at home, nitrous oxide is not the product you need — please call us and we will point you toward correct home oxygen equipment instead.
Supply policy: Medical Product BD may request facility registration details, institutional purchase authorisation or professional credentials before confirming a nitrous oxide cylinder order. This protects patients, your staff and our licence to operate.
Nitrous Oxide Cylinder Safety Instructions
Nitrous oxide is safe when handled correctly by trained people — and dangerous when it is not. These instructions apply to every nitrous oxide cylinder in your facility.
- Restrict access to authorised, trained personnel only. Nitrous oxide cylinders must never be accessible to unauthorised staff, patients or visitors.
- Treat N₂O as a strong oxidiser. It vigorously supports combustion. Prohibit smoking, open flames, sparks and hot work anywhere near cylinders.
- Keep all oil and grease away from cylinders, valves, regulators and fittings, including on gloves and hands.
- Always secure cylinders upright with chains, straps or racks to prevent falling. A falling cylinder with a damaged valve becomes an uncontrolled projectile.
- Confirm gas identity at every connection by reading the label, not by relying on cylinder position or memory.
- Use only compatible, medical-rated regulators. Never force a fitting or use an adapter to bridge mismatched connections.
- Open valves slowly and stand to the side of the regulator face during pressurisation.
- Ensure active scavenging and adequate ventilation wherever N₂O is administered, to limit occupational exposure.
- Never refill, decant or transfer nitrous oxide outside an authorised filling facility.
- Do not modify, repair, repaint or over-label any cylinder or valve.
- Store away from heat sources and direct sunlight; excessive temperature raises internal pressure.
- Transport cylinders upright and restrained, in ventilated spaces — never loose in a closed passenger compartment.
- Have a documented emergency procedure for leaks, including evacuation, ventilation and isolation steps.
- Never substitute N₂O for medical oxygen. They are entirely different products with entirely different indications.
- Prohibit any non-clinical use. Recreational inhalation can cause hypoxia, permanent neurological damage and death, and exposes your facility to serious legal liability.
Emergency note: If a significant leak occurs, evacuate and ventilate the area, prevent ignition sources, and do not re-enter until the area is confirmed safe. Contact your supplier and, where required, the relevant authorities.
Nitrous Oxide Cylinder Price in Bangladesh
Pricing for a nitrous oxide cylinder in Bangladesh depends on cylinder size, whether the cylinder is purchased outright or supplied on a deposit/exchange basis, the fill volume, and your delivery location. Because medical gas pricing shifts with supply conditions, we quote at the time of order rather than publishing figures that go stale.
| Product | Price (BDT) |
|---|---|
| Nitrous Oxide Cylinder — small 5kg | ৳ 11,500 |
| Nitrous Oxide Cylinder — medium (clinic/small hospital) | ৳ 15,000 |
| Nitrous Oxide Cylinder — large (hospital/manifold) | Call for current quote |
| Nitrous Oxide Cylinder Refill — small 5kg | ৳ 3,700 |
| Nitrous Oxide Cylinder Refill — large | ৳5,500 |
| Cylinder Trolley / Wall Bracket | Call for current quote |
| Bulk & Institutional Contract Supply | Custom quotation |
Call 01811122698 or WhatsApp for today’s confirmed nitrous oxide cylinder price, including delivery to your facility. Institutional buyers can request a formal written quotation for tender and procurement files.
Frequently Asked Questions
1. What is a nitrous oxide cylinder used for in Bangladesh? A nitrous oxide cylinder supplies medical-grade N₂O to hospitals, dental clinics and surgical centres for anaesthesia and analgesia procedures performed by qualified healthcare professionals under institutional protocols.
2. Can I buy a nitrous oxide cylinder for personal or home use? No. Nitrous oxide cylinders are supplied to registered healthcare facilities and authorised institutional buyers only. They are not appropriate for personal, home or unsupervised use under any circumstances.
3. নাইট্রাস অক্সাইড সিলিন্ডার কি অক্সিজেন সিলিন্ডারের বিকল্প হিসেবে ব্যবহার করা যায়? না, একেবারেই নয়। নাইট্রাস অক্সাইড (N₂O) এবং মেডিকেল অক্সিজেন সম্পূর্ণ আলাদা দুটি গ্যাস। শ্বাসকষ্ট, COPD, অ্যাজমা বা অপারেশন-পরবর্তী রোগীর জন্য অবশ্যই মেডিকেল অক্সিজেন সিলিন্ডার প্রয়োজন। নাইট্রাস অক্সাইড কখনোই অক্সিজেন থেরাপির বিকল্প নয়।
4. How is nitrous oxide different from medical oxygen? Medical oxygen supports breathing and is used for oxygen therapy and resuscitation. Nitrous oxide is a pharmacologically active anaesthetic and analgesic gas used only during supervised clinical procedures. They are never interchangeable.
5. বাংলাদেশে নাইট্রাস অক্সাইড সিলিন্ডারের দাম কত? নাইট্রাস অক্সাইড সিলিন্ডারের দাম সিলিন্ডারের সাইজ, গ্যাসের পরিমাণ, কেনা নাকি এক্সচেঞ্জ পদ্ধতি, এবং ডেলিভারি এলাকার উপর নির্ভর করে ভিন্ন হয়। বর্তমান দাম জানতে ০১৮১১১২২৬৯৮ নম্বরে কল করুন বা WhatsApp করুন। হাসপাতাল ও প্রতিষ্ঠানের জন্য লিখিত কোটেশন দেওয়া হয়।
6. What size nitrous oxide cylinder does a dental clinic need? Most single-chair or small dental practices operate well with smaller cylinders on a two-cylinder rotation — one in use, one spare. Share your monthly sedation case volume with us and we will recommend a suitable size.
7. How do I know how much gas is left in a nitrous oxide cylinder? Because N₂O is stored as a liquid, the pressure gauge stays roughly constant until the liquid is exhausted. Contents should be tracked by weighing the cylinder and comparing against the stamped tare weight.
8. নাইট্রাস অক্সাইড সিলিন্ডার কীভাবে সংরক্ষণ করতে হয়? সিলিন্ডার সবসময় খাড়া অবস্থায়, চেইন বা স্ট্র্যাপ দিয়ে বেঁধে, ভালো বাতাস চলাচল করে এমন নিরাপদ ও তালাবদ্ধ জায়গায় রাখতে হবে। তাপ, সরাসরি রোদ, বৈদ্যুতিক যন্ত্রপাতি এবং দাহ্য পদার্থ থেকে দূরে রাখুন। ভরা ও খালি সিলিন্ডার আলাদা করে চিহ্নিত রাখুন।
9. Can I refill a nitrous oxide cylinder myself? Absolutely not. Filling, refilling, decanting and gas transfer must be carried out only by authorised medical-gas facilities with the correct equipment and licensing. Attempting it yourself is extremely dangerous and unlawful.
10. Do you deliver nitrous oxide cylinders outside Dhaka? Yes. We dispatch nationwide to Chattogram, Sylhet, Khulna, Rajshahi, Barishal, Rangpur and Mymensingh, typically within one to two days depending on destination and cylinder size.
11. What certification should I check before accepting a cylinder? Verify gas identification and colour coding, water capacity and tare weight markings, test pressure, hydrostatic test date, fill date and batch reference, and manufacturer identification. Reject any cylinder with missing or illegible markings.
12. ডেন্টাল ক্লিনিকে নাইট্রাস অক্সাইড ব্যবহারের জন্য কী কী প্রয়োজন? প্রশিক্ষিত ও যোগ্য ডেন্টাল প্র্যাকটিশনার, উপযুক্ত সিডেশন সরঞ্জাম, স্ক্যাভেঞ্জিং সিস্টেম, রোগী মনিটরিং ব্যবস্থা, নিরাপদ সিলিন্ডার স্টোরেজ এবং প্রতিষ্ঠানের নিজস্ব প্রোটোকল প্রয়োজন। ক্লিনিক্যাল সিদ্ধান্ত সবসময় যোগ্য চিকিৎসকের।
13. Is a nitrous oxide cylinder safe to keep in a hospital ward? Only in a compliant, ventilated, access-controlled storage area with cylinders secured upright and away from heat and ignition sources. General ward storage without those controls is not acceptable.
14. Do you supply regulators and fittings with the cylinder? Regulators, trolleys and brackets are available separately. Send us a photo of your existing regulator inlet or manifold connection and we will confirm the correct match before dispatch.
15. What warranty applies to a nitrous oxide cylinder? Warranty coverage follows the manufacturer’s and filler’s terms, which we confirm in writing at order. Always verify cylinder certification and test-date requirements before accepting delivery.
Order Your Nitrous Oxide Cylinder from Medical Product BD
Your theatre list should never wait on a medical gas order. When your facility needs a certified nitrous oxide cylinder delivered correctly and documented properly, our team in Mirpur-2 is ready to help.
📞 Call Now: 01811122698 💬 WhatsApp: 01811122698 ✉️ Email: [email protected] 📍 Address: Block A, Road 5, House 12, Mirpur-2, Dhaka 1216





Reviews
There are no reviews yet.